Thermal Cuttofs  /  SW-2 Series

cce5a1d88e70338aaefbf2f4bbdc0297.png

◎ CONSTRUCTION


   d126d8f6b0308f6f14b49a9b3cfe489a.png


 ◎ ELECTRICAL

RATED VOLTAGE : 250V, ac
RATED CURRENT : 2A
INTERRUPTING CURRENT : 250V, ac 3A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 30A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.


◎ TEMPERATURE


Cat NO.TfCutoff temperatureThK.I.SULC-ULVDETUVMITI
SW-211T102℃ 98℃+2℃,-2℃70℃
SW-210T115℃110℃+3℃,-2℃85℃
SW-215T130℃125℃+2℃,-2℃95℃
SW-216T133℃129℃+2℃,-2℃100℃
SW-217T139℃135℃+3℃,-3℃105℃
SW-225T150℃145℃+3℃,-2℃120℃

                                                                                     UL file NO : E126429  ● = Approved  □ = Applied


◎ DIMENSIONS

                       drawing.png 

dimension(mm)abcde
mm67.0 ±3.5 9.5 ±0.567±3.52.5±0.20.6±0.05



◎ MARKING
     Each TCO shall be marked with:
     Cat No. : SW - 2XX T
     Ratings : Rated voltage (V), Rated current (A) 
     Rated Functioning temperature (℃) 
     Approval Mark