Module_VHP-100 (Capacitance)
1. Scope of application
This specification is applied to the humidity module VHP-100 series.
2. Configuration
3. Electrical characteristics
3 - 1. Humidity Sensor : VNCH-100
3 - 2. Supply voltage(Vin) : 5VDC
3 - 3. Current consumption : MAX 1.3mA
3 - 4. Temperature coefficient : -0.1 %RH/℃
3 - 5. Operation temperature : -40 ~ 80℃
3 - 6. Operation humidity : 0 ~ 100%RH (non-condensing)
3 - 7. Voltage output : 0 ~ 3.3V (at 25℃, 0~100%RH Full scale)
3 - 8. Sensitivity : 31mV/%RH
3 - 9. Response time : 15 sec.
3 - 10. Humidity Accuracy : ±3%RH (at 25℃, from 20%RH to 90%RH)
3 - 11. Storage temperature range : -40 ~ 90℃
3 - 12. Storage humidity range : 0 ~ 100%RH
3 - 13. Typical output characteristics (Reference) at 25℃, Vin = DC 5.0V Unit :mV
| 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 95 |
Output | 330 | 660 | 990 | 1320 | 1650 | 1980 | 2310 | 2640 | 2970 | 3135 |
3 - 14. Standard Characteristics
3 - 15. Temperature Dependence(Reference) : ±5%RH (Vin=5.0VDC, 30%RH to 80%RH,
Temp. Range 10 to 40℃(based on 25℃)
3 - 16. Voltage Dependence(Reference) : ±5%RH (Vin=5.0VDC, 30%RH to 80%RH,
Voltage Range 4.75 to 5.25VDC(based on 25℃)