1. Scope of application
This specification is applied to the Temperature & humidity sensing module
2. Configuration
Module No. | Connector Type | Thermistor | Drawing | |
1 | VVR-1 | Wafer(20010WR-03) | None | Fig.1 |
2 | VVR-1(T) | Wafer(20010WR-04) | Option |
3. Electrical characteristics
3.1 Sensing Element (Humidity) : Humidity Sensor
3.2 Supply Voltage : DC 5V ±5%
3.4 Operating
3.5 Operating
3.6 Storage Temperature Range : -20 ~ 70℃
3.7 Storage Humidity Range : 0 ~ 95%
3.8 Humidity Detecting Range : 20 ~ 95%
3.9 Humidity output signal (Reference)
RH (%) | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
Output(mV) | 660 | 990 | 1320 | 1650 | 1980 | 2310 | 2640 | 2970 |
3.10 Accuracy : ±5% (at 25℃)
3.11 Temperature output signal : NTC Thermistor
R(25℃) = 10㏀±3%
B(25/85℃)= 3435K±1%
Temp. (℃) | 0 | 10 | 20 | 25 | 30 | 40 | 50 | 60 |
Resistance(㏀) | 27.76 | 18.12 | 12.12 | 10.0 | 8.30 | 5.80 | 4.13 | 3.00 |